AC External Rotor Motor Axial Fan for Ventilation 450mm

Product Details
Customization: Available
Material: Iron
Usage: for Manufacture
Manufacturer/Factory
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
10000000 RMB
Plant Area
>2000 square meters
  • AC External Rotor Motor Axial Fan for Ventilation 450mm
  • AC External Rotor Motor Axial Fan for Ventilation 450mm
  • AC External Rotor Motor Axial Fan for Ventilation 450mm
  • AC External Rotor Motor Axial Fan for Ventilation 450mm
  • AC External Rotor Motor Axial Fan for Ventilation 450mm
  • AC External Rotor Motor Axial Fan for Ventilation 450mm
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Installation dimensions
  • Detailed Photos
  • After Sales Service
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
YWF Series
Pressure
Low Pressure
Certification
RoHS
Color
Black
Model No.
Ywf6d-450
Transport Package
Carton
Specification
Long Tube type
Trademark
JIAYI
Origin
Wenling, China
HS Code
8414599050
Production Capacity
5000pieces/Month

Product Description

Product Description

AC External Rotor Motor Axial Fan for Ventilation 450mm
Unlike conventional motors whose rotors are on the inside of a wound stator, external rotor motors have their rotor on the outside. This presents unique advantages to the fan manufacturer and user as detailed below:


An extremely compact, therefore space saving unit, is produced by utilising the external rotor component as the hub of a fan impeller.
Precision balancing is assured as the hub and impeller becomes one integrated unit of short axial length.
Heat is very effectively removed in the airstream, assisted by the fan impeller that acts as a rotating heat sink of appreciable surface area.
Speed control is then possible by low cost voltage variation because the extra heat generated in the rotor under speed control is lost directly into the airstream.
Air filters can be 'saved' when clean but 'air flow compensated' when dirty by the tendency of centrifugal fans to speed-up as flow resistance increases. The increase in speed is more pronounced when using external rotor motors.
In general, the external rotor principle leads to small efficient motors, ideal for saving space within equipment.

EXTERNAL ROTOR FANS

Fans housing stator and windings inside the rotor are compact, well-balanced, with widely adjustable rotation speed and good motor cooling. Built with insulation system (Class F) and integrated thermal protection. Axial fans are characterised by a series of unique properties of being quiet, robust and thermal-shielding. Useful in all those situations in a system with low pressure drop (therefore not very high resistance), the axial fans guarantee a large airflow rate.

The external rotor axial flow fan has the characteristics of compact structure, convenient installation, reliable operation, low noise, energy saving and high efficiency. The products are widely used in hotels, restaurants, industrial and mining enterprises, office buildings, theaters and other building facilities, as ancillary equipment for freezers and cold storage or for ventilation and heat dissipation. (For example, it is matched with refrigeration equipment or facilities such as supermarket freezers, ice machines, air coolers, chillers, condensing units, etc., and used with dehumidifiers, evaporators, side wall fans, fire fans, central air-conditioning fans and other equipment).

The outer rotor axial flow fan is composed of fan blades, outer rotor motor, net cover, lead wire and other parts. The structure of the fan is calculated by structural finite element, and the strength check, modal analysis, harmonic response analysis and other methods are carried out to ensure that our products have the advantages of stable and reliable structure, high safety factor, small vibration, and strong anti-interference ability! According to customer requirements, Thermal protectors, junction boxes and other components can be installed, or different installation methods such as cylinder type and box type can be selected. The blades are designed according to the principles of aerodynamics, acoustic principles and acoustic performance requirements. They are twisted according to certain rules from the tip to the root. The material is made of high-quality steel or plastic. After dynamic balance verification, it has good starting performance, stable operation and low noise. 

Product Parameters
Model Rated Voltage (V) Frequency
(Hz)
Current
(A)
Input Power (W) Highest Speed (r/min) Volume
(m³)
Pressure
(Pa)
Noise db (A) Capacitor
(μF)
YWF2D-200  380 50 0.25 80 2700 1080 122 57 -
YWF2E-200 220 50 0.30 70 2650 1050 120 56 2.5
YWF4D-200  380 50 0.20 50 1400 500 60 50 -
YWF4E-200  380 50 0.20 40 1400 510 55 50 1.5
YWF2D-250 380 50 0.25 105 2650 1850 192 65 -
YWF2E-250 220 50 0.53 115 2550 1800 190 65 4
YWF4D-250  380 50 0.23 55 1450 1250 60 55 -
YWF4E-250 220 50 0.30 60 1440 1230 60 55 2.5
YWF2D-300 380 50 0.28 140 2480 3250 205 66 -
YWF2E-300 220 50 0.80 180 2550 3300 210 66 6
YWF4D-300 380 50 0.25 70 1400 1950 70 60 -
YWF4E-300 220 50 0.35 75 1400 1950 70 60 3
YWF2D-350 380 50 0.72 400 2400 4850 225 73 -
YWF2E-350 220 50 1.80 400 2350 4750 223 72 10
YWF4D-350 380 50 0.45 130 1400 3270 93 64 -
YWF4E-350 220 50 0.55 125 1400 3270 93 64 4
YWF2D-400 380 50 1.05 580 2350 6480 240 74 -
YWF2E-400 220 50 2.40 510 2280 6100 240 80 12
YWF4D-400 380 50 0.60 180 1400 4800 125 68 -
YWF4E-400 220 50 0.90 190 1400 4800 125 68 6
YWF40D-450 380 50 0.53 210 1390 5410 155 70 -
YWF4E-450 220 50 1.25 280 1380 5380 150 69 10
YWF6D-450 380 50 0.42 155 950 4680 100 60 -
YWF6E-450 220 50 0.85 165 1390 4650 100 60 8
YWF4D-500 380 50 0.62 280 1390 8850 192 72 -
YWF4E-500 220 50 1.75 370 1390 8850 190 72 12
YWF6D-500 380 50 0.90 210 950 5800 125 65 -
YWF6E-500 220 50 0.90 230 950 5800 125 65 8
YWF4D-550  380 50 0.90 450 1350 10800 215 74 -
YWF4E-550 220 50 2.50 500 1350 10800 215 74 12
YWF6D-550 380 50 1.00 210 950 6500 135 68 -
YWF6E-550 220 50 1.10 300 950 6500 135 68 8
YWF4D-600 380 50 1.55 680 1380 13000 230 75 -
YWF4E-600 220 50 3.25 750 1380 13000 230 75 15
YWF6D-600 380 50 1.20 360 930 9600 150 70 -
YWF6E-600 220 50 1.40 450 900 9500 150 70 10
 
Installation dimensions

 

AC External Rotor Motor Axial Fan for Ventilation 450mm
 
Model A B C D E K F G a b
200 220 270 220 270 210   110 148 12 53
250 270 320 270 320 260 270 120 148 12 53
300 320 370 320 370 310 320 125 158 12 53
350 370 420 370 420 365 375 130 168 12 41
400 420 470 420 470 415 425 140 181 12 57
500 520 570 520 570 515 525 155 183 12 57
600 610 670 610 670 615 625 209 218 12 57
Detailed Photos

 

AC External Rotor Motor Axial Fan for Ventilation 450mm
AC External Rotor Motor Axial Fan for Ventilation 450mm
AC External Rotor Motor Axial Fan for Ventilation 450mm
After Sales Service

Our service:
 Marketing Service

100% tested CE certified blowers.Professional advice for model selection and further market development.

Pre-sales service: 
•We are a sales team, with all technical support from engineer team.
•We value every inquiry sent to us, ensure quick competitive offer within 24 hours.
•We cooperate with customer to design and develop the new products. Provide all necessary document.

After-sales service:
•We respect your feed back after receive the fan.
•We provide 1years warranty after receipt of fan..
•We promise all spare parts available in lifetime use.
•We loge your complain within 24 hours.

1. SAFETY REGULATIONS AND NOTES
Please read these operating instructions carefully before starting to work with the device. Observe the following warnings to prevent malfunctions or physical damage to both property and people. These operating instructions are to be regarded as part of this device. If the device is sold or transferred, the operating instructions must
accompany it. These operating instructions may be duplicated and forwarded for
information about potential dangers and their prevention.

1.1 Levels of hazard warnings
These operating instructions use the following hazard levels to indicate potentially hazardous situations and important safety regulations:
DANGER
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Compliance with the measures is mandatory.
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Exercise extreme caution while working.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or damage of property.
NOTE
A potentially harmful situation can occur and, if not avoided, can lead to property damage.
1.2 Staff qualification
The device may only be transported, unpacked, installed, operated, maintained and otherwise used by abled, qualified, trained and authorised technical staff. Only authorised specialists are permitted to install the device, to carry out a test run and to perform work on the electrical installation.
1.3 Basic safety rules
Any safety hazards stemming from the device must be re-evaluated once it is installed in the end device. Observe the following when working on the unit: Do not make any modifications, additions or conversions to the device without the approval.
1.4 Electrical voltage
Check the electrical equipment of the device at regular intervals, refer to Safety test. Replace loose connections and defective cables immediately

Company Profile

AC External Rotor Motor Axial Fan for Ventilation 450mm
Zhejiang Jiayi Fan Co., Ltd. was established in 2003. It is a modern private enterprise focusing on the research, development, production and sales of ventilation equipment. The company is headquartered in Daxi Town, Wenling City, Zhejiang Province, which is the "Hometown of Pumps in China", and has branches across the country; the production base is located in the East New District of Wenling City.

The main products of the company: all kinds of portable, mobile, oil-proof and moisture-proof axial flow fan series; medium, low and high pressure centrifugal fan series; boiler type draft fan series; mixed flow, diagonal flow fan series; industrial exhaust fan series; blower series and Y series; air compressor series and three-phase asynchronous motor, etc.; and can design and produce various non-standard and special exhaust equipment and special fans according to customer requirements.

Sincerely thank domestic and foreign customers for their long-term trust and love for A and B fans, and welcome you to visit and guide us at any time. With your support, we are more confident to manufacture ventilation equipment products that meet the needs of social development. Let us work together, help each other, coexist and prosper, and create unlimited business opportunities.
FAQ
Q1: What's the terms of trade?
A1: FOB,CFR,CIF or EXW are all acceptable.
 
Q2: What's the terms of payment?
A2: T/T,L/C at sight or cash.
 
Q3: How long is your delivery time?
A3: Generally it is 5-10 days if the goods are in stock or it is 20-30 days if the goods are not in stock, it is according to quantity.
 
Q4: What is the advantage about your company?
A4: Our company has professional team and professional production line.
 
Q5: If we travel to China to checking your facility, are you welcome?
A5: Of course,  We will provide the whole accompany upon your arrivial. Warm Welcome!
 
Q6: How Many Years of your company working in this industry?
A6: We have over 20-year experience in this field.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier