Zhejiang Dkt Series Double Air Inlets Air Conditioning Air Conditioner Refrigeration Fan

Product Details
Customization: Available
Material: Carbon Steel
Usage: for Air Conditioner, for Manufacture, for Refrigerate
Still deciding? Get samples of US$ 100/Piece
Request Sample
Manufacturer/Factory
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
10000000 RMB
Plant Area
>2000 square meters
  • Zhejiang Dkt Series Double Air Inlets Air Conditioning Air Conditioner Refrigeration Fan
  • Zhejiang Dkt Series Double Air Inlets Air Conditioning Air Conditioner Refrigeration Fan
  • Zhejiang Dkt Series Double Air Inlets Air Conditioning Air Conditioner Refrigeration Fan
  • Zhejiang Dkt Series Double Air Inlets Air Conditioning Air Conditioner Refrigeration Fan
  • Zhejiang Dkt Series Double Air Inlets Air Conditioning Air Conditioner Refrigeration Fan
  • Zhejiang Dkt Series Double Air Inlets Air Conditioning Air Conditioner Refrigeration Fan
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Installation Instructions
  • Feature
  • Detailed Photos
  • After Sales Service
  • Company Profile
  • TIPS
Overview

Basic Info.

Model NO.
DKT250
Flow Direction
Axial Flow
Pressure
High Pressure
Certification
RoHS, ISO, CE, CCC, Saber
Color/Design
Customized
Application
Industrial Construction
Performance
Low Noise Fan
Warranty
1year
Wind Flow(M3/H)
2100-3000
Transport Package
Wooden Case
Specification
DKT SERIES
Trademark
JIAYI
Origin
Wenling, China
HS Code
8414599050
Production Capacity
800000pieces/Month

Product Description

Product Description

Zhejiang Dkt Series Double Air Inlets Centrifugal Fan for Commercial Mall Air Exhaust
The dkt type external rotor centrifugal air conditioner fan has the characteristics of large air volume, low noise, compact structure, firmness and durability, beautiful appearance, and convenient installation and use. The fan is widely used in various air-conditioning units, air curtains, cooling and heating fans, etc. It can also be used for indoor ventilation in industrial and mining enterprises and public places. The medium it transports is air and other non-self-igniting gases that are harmless to the human body. No particulate matter is allowed in the gas, and the dust content is not more than 150mg/m3. d dkt type outer rotor centrifugal air conditioner fan is mainly composed of impeller, casing, outer rotor motor and other main components.

The impeller is made up of dozens of forward-curved blades riveted to the wheel cover and the middle plate. Each piece is made of stamping dies, with accurate and reliable dimensions and lines, good air performance, and is corrected by static and dynamic balance, running smoothly and with low noise; The appearance is beautiful and generous; the motor adopts the outer rotor type, which is built in the casing and directly connected with the impeller.

The purpose of the fan
DKT type air-conditioning fans are mainly used for various air-conditioning units, air curtains, cooling and heating fans and other products, and can also be used for ventilation in industrial and mining enterprises and civil buildings.

The structure of the fan
DKT fan is mainly composed of impeller, volute, motor and other main components. The impeller is formed by riveting the forward curved blades, the wheel cover and the middle plate. All parts are made of stamping dies, the size and profile are accurate and reliable, the aerodynamic performance is good, and after the dynamic and static balance correction, the movement is stable and the noise is low. The volute is made of special equipment for biting and wrapping, which is sturdy and durable, and has a beautiful appearance. The motor adopts the outer rotor type, which is built in the volute and directly connected to the impeller. It has a compact structure, stable rotation and low noise.

Product Parameters
No. Model Power(KW-P) Wind Flow(m3/h) Pressure(Pa) Noise (Db(a))
2 11-45 DKT200 0.25-4 900-1500 315-295 ≤64
2.25 10-63 DKT225 0.45-4 2300-2900 325-300 ≤66
2.5 12-45 DKT250 0.75-4 2100-3000 515-475 ≤64
8-34   0.75-4 1800-2600 550-450 ≤64
12-58   0.85-4 2500-4000 400-270 ≤67
2.8 10-60 DKT280 1.1-4 2600-4600 490-420 ≤69
9-67 DKT280 0.55-6 2100-3600 270-190 ≤64
3 9-56 DKT300 1.8-4 3800-5500 620-600 ≤72
9-57   2.2-4 4300-6500 720-700 ≤72
16-47   1.1-6 3100-5100 425-405 ≤67
3.5 11-48 DKT350 3.0-4 5300-7500 425-405 ≤75
10-48   1.5-6 3100-6100 355-330 ≤68
4 12-45 DKT400 3.0-6 5100-9100 610-590 ≤72
4.5 15-42   5.5-6 7500-13000 850-800 ≤77
11-68   7.5-6 13000-19000 750-700 ≤78
13-42   4.0-6 5600-11000 800-750 ≤75
 
Installation Instructions

Zhejiang Dkt Series Double Air Inlets Air Conditioning Air Conditioner Refrigeration Fan
Zhejiang Dkt Series Double Air Inlets Air Conditioning Air Conditioner Refrigeration Fan

Feature

Max. Ambient Temp: <130ºC
Relative humidity: ≤98%
Rated voltage: 220V/380V
Cooling Method: IC411, Protection Class: IP54/IP55
Insulation Class: Class B(130ºC), Class F(155ºC), Class H(180ºC)
Fan Blade: carbon steel and stainless steel
Motor: Single speed/Double speed Motor/ Explosion-proof Motor
Frame: carbon steel 

1. Good looking: The fan body be stamp by precise mould with Power coating;
2. Centrifugal fan with forwardward curved impeller;
3. Compact structure, various size for option, easy for installation;
4. Using standard size for the inlet and outlet, it coule be connect with tubing directely;
5. Using extenal rotor motor, extremely low noise.
6. Application: Where needs air ventilation, such as Hotel, Meeting room, Restaurant,Station, Supermarket, Airport, ect...
7. Durable external rotor motor with thermal link, Matching speed-controllers is available.

Detailed Photos

Zhejiang Dkt Series Double Air Inlets Air Conditioning Air Conditioner Refrigeration FanZhejiang Dkt Series Double Air Inlets Air Conditioning Air Conditioner Refrigeration FanZhejiang Dkt Series Double Air Inlets Air Conditioning Air Conditioner Refrigeration Fan
Zhejiang Dkt Series Double Air Inlets Air Conditioning Air Conditioner Refrigeration Fan
Zhejiang Dkt Series Double Air Inlets Air Conditioning Air Conditioner Refrigeration Fan

After Sales Service

Our service:
 Marketing Service

• 100% tested CE certified blowers.Professional advice for model selection and further market development.

Pre-sales service: 
• We are a sales team, with all technical support from engineer team.
• We value every inquiry sent to us, ensure quick competitive offer within 24 hours.
• We cooperate with customer to design and develop the new products. Provide all necessary document.

After-sales service:
• We respect your feed back after receive the fan.
• We provide 1years warranty after receipt of fan..
• We promise all spare parts available in lifetime use.
• We loge your complain within 24 hours.

Company Profile

Zhejiang Dkt Series Double Air Inlets Air Conditioning Air Conditioner Refrigeration FanZhejiang Jiayi Fan Co., Ltd. was established in 2003. It is a modern private enterprise focusing on the research, development, production and sales of ventilation equipment. The company is headquartered in Daxi Town, Wenling City, Zhejiang Province, which is the "Hometown of Pumps in China", and has branches across the country; the production base is located in the East New District of Wenling City.

Enterprise development strategy: The company has always regarded quality as the fundamental, with integrity as the criterion, to create high-quality, cost-effective ventilation equipment products for users is the goal pursued by companies A and B.

The main products of the company: all kinds of portable, mobile, oil-proof and moisture-proof axial flow fan series; medium, low and high pressure centrifugal fan series; boiler type draft fan series; mixed flow, diagonal flow fan series; industrial exhaust fan series; blower series and Y series; air compressor series and three-phase asynchronous motor, etc.; and can design and produce various non-standard and special exhaust equipment and special fans according to customer requirements.

Sincerely thank domestic and foreign customers for their long-term trust and love for A and B fans, and welcome you to visit and guide us at any time. With your support, we are more confident to manufacture ventilation equipment products that meet the needs of social development. Let us work together, help each other, coexist and prosper, and create unlimited business opportunities

TIPS

How to use the centrifugal fan correctly  
   Even if the user can choose a good one when choosing a centrifugal fan, if the user does not strictly follow the instructions in use, it will reduce the use effect of the fan and even shorten the service life of the centrifugal fan, which is also a problem for the user. This is a huge loss. The correct use of the centrifugal fan can not only ensure its use effect, but also prolong the service life of the fan to a large extent. Therefore, many users want to know what is the correct use to use What about reduced damage to the fan? Today we will introduce some tips for using centrifugal fans. I believe that as long as the user masters these, the efficiency of the fan can be improved to a certain extent.

        The use of the centrifugal fan starts from its start-up. Sometimes there will be a problem of startup failure or very long startup time. There are many reasons for this situation. If the motor does not drag, check the setting of the safety mechanism; if the rated power of the motor is too low, replace the motor; if the starting procedure is not correct, adjust the starting equipment; if the power consumption when starting is too large, verify that the starting Check whether the gas flow control mechanism is in the closed position when the rotor is stuck; if the rotor is stuck, turn the fan by hand to check and investigate the cause of the jam (friction, obstruction, etc.); if the voltage at the motor wiring is too low, the Check power cord voltage - if loss is excessive, increase power cord.

        Many times users will find that the impeller is always consuming energy in vain. The gas circulates through the leakage between the front cover and the current collector. A certain gap must be maintained, between the front cover of the centrifugal fan and the collector and between the casing and the rotating shaft. To ensure the reliability of fan rotation. This can alleviate this phenomenon to a great extent.

        The problem that often occurs in the use of centrifugal fans is the vibration of the fan. It is not a simple matter to fundamentally solve this problem, but it is a very good way to reduce the speed of the fan, and the effect of this method is also very obvious. on. However, it is still necessary for the user to judge which method to use according to the specific situation of the fan used to be more reasonable.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier